A Professional Maintenance Strategy of Polystyrene Foam Densifier
Now the green economy has come into people’s vision, more and more people have constraints on whether the enterprise is green development. For enterprises, the recycling, regeneration, and utilization of polystyrene foam have become an important event. Because of this, many enterprises choose polystyrene foam densifiers to recycle.
As large-scale equipment, if the maintenance of polystyrene foam densifier is improper, it is easy to break down or damage, so in the factory, the maintenance of this kind of recycling equipment is very important. This article will give you a detailed description of how to maintain the polystyrene foam densifier.
(1) Wires and cables shall be protected from damage, corrosion, excessive bending, etc.
(2) To prevent it from knotting, in the end, don’t get dirty in a dirty place.
(3) Wires and cables shall be in good lubrication condition.
(4) Check the quality of the wires when replacing them.
(5) If one-sixth of the cables are broken, they should be replaced. Figure 5 shows the convolution method
(6) Check the sealing condition of the in-cylinder joint and high-pressure hose regularly.
(7) No.46 anti-wear hydraulic oil is used in the oil cylinder, and no impurity of more than 0.06mm is allowed to enter. It is recommended to change the oil once a year.
(8) Clean the filter screen of the oil tank regularly.
(9) Cut off the power. Cut off the power. The piston rod must contract in the cylinder.
(10) When the riser is folded, the moving parts including the hydraulic cylinder, pulley, and upper (lower) slide block must be fixed.
(11) Every 40 days, check whether there are oil drops on the hydraulic system, and conduct it regularly to prevent joint looseness caused by mechanical vibration.
(12) Before the hydraulic system was transferred out of the factory, the hydraulic system had changed. Check the level of hydraulic oil regularly. When it is lower than the oil label, add hydraulic oil until it is between the oil labels
(13) When the cold press is used for one year, it should be replaced with new hydraulic oil.
(14) Every 60 days, lubricating oil should be added to the reducer and screw drive parts, as well as crushing knife drive bearings, to prevent damage to components caused by dry friction.
(15) Every 60 days, the screw on the machine connector should be tightened to prevent the screw loosening caused by machine vibration.
(16) According to the working environment and cleaning PLC cable plug, soot will blow the electronic control box.
(17) Check the photoelectric switch regularly for dust and clean it if any.
(18) Regularly check that the wires are connected in the correct way. If the wires are damaged or aged, proper measures must be taken.
(19) Check the components regularly for proper operation. If any part is burnt or damaged, please replace it.